In order to analyze the bone matrix mineralization, mechanical properties and intra-specimen variations at the microscopic scale, tibiae were collected from four mice (2 males, 2 females), randomly selected from the wild type group and from
the oim group. The bones were fixed in 70% ethanol (1 week), dehydrated using a graded ethanol series (70, 80, 95 and 99% for 48 h in each), and substituted with xylene (24 h). The specimens were then infiltrated for 48 h in two successive changes of pure methyl methacrylate (MMA) replaced by two changes of MMA + α-azo-iso-butyronitrile Ixazomib price (24 h) and finally polymerized slowly at 37 °C (all chemicals purchased from VWR, UK). The tibiae were sectioned transversally at the mid-diaphysis with a low speed diamond saw (Isomet, Buehler GmbH, Germany) and the cross-sections were ground with increasingly finer ABT-888 nmr grades of carbide papers (from P500 to P4000) and finally polished with diamond slurry (diameter: 0.25 and 0.05 μm). The tibia mid-diaphyseal cross-sections were carbon coated and analyzed using qBSEM in an EVO®MA15 scanning electron microscope (Zeiss UK Ltd., UK) operated at 20 kV, at a working distance of 13 mm, and a beam current of 0.5 nA. The qBSEM digital images were recorded with a nominal magnification
of 137 × (field width: 2.133 mm, pixel size: 1.04 μm). The image backscattered electron (BSE) current signal (digitized in gray levels) were standardized against the BSE signals of monobromo and monoiodo dimethacrylate standards which span the signal range found for mineralized tissues: 0 (black, monobrom) representing osteoid and 255 (white, monoiod) representing Ribociclib purchase highly mineralized bone [28] and [29]. To facilitate visualization, the gray-level range was also divided into 8 equal size classes
(1–32, 33–64, 65–96, 97–128, 129–160, 161–192, 193–224, 225–255), representing no mineralization (class 1) to very high bone mineralization (class 8). The distribution of pixels into the different bone mineralization classes was then calculated and provides an estimate of the amount and distribution of bone mineral within a sample. For numerical analysis, each cross section image was automatically divided by a custom Matlab program into 12 areas corresponding to the periosteal, mid-cortex and endosteal sectors of the anterior, lateral, posterior and medial cross section quadrants. The mean pixel gray-level value in each sector was then calculated as an estimate of the mean amount of bone mineral in this sector. Nanoindentation tests were conducted on the same tibia mid-diaphyseal cross-sections to a maximum load of 8 mN at a constant loading rate of 800 μN/s in the longitudinal axis using the TI700 UBI (Hysitron, MN, USA) with a Berkovich diamond tip.