10% +/- 4 04% Temperature data showed a difference between theor

10% +/- 4.04%. Temperature data showed a difference between theory and imaging performance

of -0.28% +/- 0.22%. Images of polyacrylamide test objects showed detectability of an approximately 1% sound speed difference in a 2.4-mm cylindrical inclusion with a contrast to noise ratio of 7.9 dB.\n\nConclusions-An automated breast scanner offers the potential to make consistent automated tomographic images of breast backscatter, sound speed, and attenuation, potentially improving diagnosis, particularly in dense breasts.”
“Background: Most previous studies on hallux valgus focused on the possible relationship between this deformity and muscles and/or ligaments in the foot and lower leg. Very little is known about the relationship between hallux valgus and alignment of the proximal joints. The aims of the present study were to determine the LY2835219 supplier extent to which lower extremity alignment characteristics of the hip, knee, ankle, NCT-501 and foot were

related to the manifestation of hallux valgus and to identify variables predicting its development in women.\n\nMethods: A group of 25 women with hallux valgus and 24 control women, age 51 to 80 years, were interviewed and screened for the current study. Measurements recorded were hallux valgus angle; intermetatarsal angle; a set of body physique measures (eg, height); range of motion at the hip, knee, ankle, and foot joints; general hypermobility; lower extremity alignment (eg, tibiofemoral angle); and 9 anatomical anomalies (eg, knee valgus/varum).\n\nResults: Women with hallux valgus manifested notably higher range of motion at their joints, different lower extremity alignment, higher prevalence of general joint hypermobility, and higher prevalence of anatomical anomalies compared with controls. Estimated marginal means for most joint range of motion and lower extremity

alignment measurements were notably higher for the hallux valgus group.\n\nConclusion: Lower extremity alignment and joint range of motion were correlated with hallux valgus. Future studies could possibly identify anatomic risk factors for the development of hallux valgus, nonsurgical methods of prevention and adjunctive surgical methods of treatment.”
“Eu-doped (Bi0.5Na0.5)(0.94)Ba0.06TiO3 (BNBT6-xEu, x=0.00-2.00 at%) Go 6983 lead-free piezoelectric ceramics have been synthesized by the solution combustion method. The effect of Eu doping concentration on the phase structure, microstructure and electrical properties of BNBT6 ceramics has been investigated. The XRD analysis confirms that the europium additive incorporates into the BNBT6 lattice and results in a phase transition from the coexistence of rhombohedral and tetragonal phases to a more symmetric pseudocubic phase. The SEM images indicate that the europium additive has little effect on the ceramic microstructure and the average grain size is about 2.0 mu m. The electrical properties of BNBT6 ceramics can be improved by appropriate Eu doping.

Comments are closed.